ACCARE Handheld Pulse Oximeter


The HS series handheld pulse oximeters quickly and painlessly measure oxygen saturation (SpO²) and pulse rate (PR) – two key vital parameters for assessing respiratory function. They are indispensable in clinical practice, emergency response, and home monitoring.

The ACCARE handheld pulse oximeters from Accurate are designed to reliably cover all age groups – from newborns to children to adults. Special sensors and highly precise measurement technology enable stable readings even in cases ofpoor circulationorrestless patients.

Whether in the intensive care unit, in emergency services, or during home follow-up – with our devices, you are prepared for any situation.

Handpulsoximeter HS-10A

The HS-10A handheld pulse oximeter from Accare is a versatile device when it comes to obtaining reliable values for the

oxygen saturation (SpO2) orpulse rate (PR).It allows for non-invasive measurement for all age groups (newborns to adults) and is specifically used in hospitals, clinics, medical practices, and emergency services.

Further differences can be found in the technical specifications broken down and compared

Handheld Pulse Oximeter HS-20A

Handpulsoximeter HS-20A

Handpulsoximeter HS-20A

The ACCARE HS-20A handheld pulse oximeter enables non-invasive SpO2 detection for all age groups, including newborns, children, and adults. Thanks tostate-of-the-art multispectral analysis technologythe pulse oximeter also providesstable and precise measurements, even in cases ofpoor circulation, which often occurs in small children or older adults.The device features several functions such as data storage and anomaly alarms. In the case of abnormal values, anaudibleand visualalarm is triggered; the measurement data can also be stored in real-time.

Adjustable alarm limits

Our handheld pulse oximeters havefreely adjustable alarm limitsfor oxygen saturation (SpO2) and pulse rate (PR). This allows users to customize thresholds to the specific patient or application – whether in a clinical setting, in emergency services, or for home monitoring. In case of deviations, the devicestrigger visual and audible alarmsenabling quick responses before the patient's condition worsens.

Visueller Alarm Handpulsoximeter HS-10A
Stehende Silikonhülle Handpulsoximeter HS-10A

Thoughtful silicone cover

To protect in everyday use, each device is equipped with arobust silicone protective cover.This not only reliably protects against impacts and scratches but also features anintegrated stand,which can be determined by a locking mechanism. This allows the handheld pulse oximeter to be securely placed upright – ideal forbetter readability of the measurement valuesand foravoiding unintentional tipping overin clinical or home use. Practical, stable, and user-friendly – thought out down to the last detail.

It goes without saying for us that the protective cover is included with usin the scope of deliveryand does not need to be purchased separately!

To the shop

Available sensors for the handheld pulse oximeters HS-10A & HS-20A

Reusable sensors

Finger clip sensors

for children or adults

Fingerclip Sensor für Handpulsoximeter HS-10A & HS-20A

Ear clip sensor

for adults

Ohrclip Sensor für Handpulsoximeter HS-10A & HS-20A

Wrap sensor

made of silicone for newborns

Wrap Sensor für Handpulsoximeter HS-10A & HS-20A

Soft sensor

made of silicone for children or adults

Soft Sensor für Handpulsoximeter HS-10A & HS-20A

Technical specifications


Function / Model

Accurate HS10A

Accurate HS10-Li

Accurate HS20A

Accurate HS20-Li

Item number:

DHP01001

DHP01002

DHP01003

DHP01004

Product size:

72 x 142 x 31 mm

(LxWxH)

72 x 142 x 31 mm

(LxWxH)

72 x 142 x 31 mm

(LxWxH)

72 x 142 x 31 mm

(LxWxH)

Box size:

177 x 135 x 63 mm

(LxWxH)

177 x 135 x 63 mm

(LxWxH)

177 x 135 x 63 mm

(LxWxH)

177 x 135 x 63 mm

(LxWxH)

GTIN number:

6927394500838

6927394500852

6927394500845

6927394500869

Display type:

LCD - 2.3 inches

LCD - 2.3 inches

LCD - 2.3 inches

LCD - 2.3 inches

Display material:

Digital screen

Digital screen

LCD

LCD

Display indicators:

1

1

2

2

Battery life:

22 hours

---

22 hours

---

Battery runtime:

---

16 hours

---

16 hours

Power supply:

3x AA batteries, (1.5V)

1,600 mAh, 3.7V Lithium

Rechargeable battery

3x AA batteries, (1.5V)

1,600 mAh, 3.7V Lithium

Rechargeable battery

Charging time:

---

3 hours to 90%

6 hours to 100%

---

3 hours to 90%

6 hours to 100%

Setting time:

no

no

yes

yes

Waveform:

no

no

yes

yes

Perfusion index (PI):

no

no

yes

yes

Display of PI:

Histogram

Histogram

Value

Value

Data storage:

no

no

yes

yes

Number of storage entries:

---

---

503 entries

503 entries

Storage cycles:

2 - 60 seconds

2 - 60 seconds

2 - 60 seconds

2 - 60 seconds

Setting patient data:

no

no

yes

yes

Patient groups:

Neonates, infants, adults

Neonates, infants, adults

Neonates, infants, adults

Neonates, infants, adults

Low perfusion index (PI):

0.20%

0.20%

0.20%

0.20%

Displayed uptime:

2 seconds

2 seconds

2 seconds

2 seconds

SpO2 accuracy:

70% - 100% (+/- 2)

70% - 100% (+/- 2)

70% - 100% (+/- 2)

70% - 100% (+/- 2)

PR accuracy:

25 - 250 beats per minute

(+/- 3 beats)

25 - 250 beats per minute

(+/- 3 beats)

25 - 250 beats per minute

(+/- 3 beats)

25 - 250 beats per minute

(+/- 3 beats)

PI accuracy:

0.20% - 20%

0.20% - 20%

0.20% - 20%

0.20% - 20%

Volume:

45 - 85 dB

45 - 85 dB

45 - 85 dB

45 - 85 dB

Protection level against

liquid ingress:

IPX2

IPX2

IPX2

IPX2

Frequently Asked Questions

Here you will find some frequently asked questions about our company.

A pulse oximeter is a medical device for non-invasive measurement of arterial oxygen saturation (SpO₂) and pulse rate. It provides important vital parameters in real-time and is an essential monitoring tool in both preclinical and clinical settings.

  • Finger pulse oximeters: Compact, ideal for quick use on patients, often without external sensors. Less suitable for long-term monitoring.

  • Handheld pulse oximeters: Portable devices with external sensors. Higher measurement accuracy, extended features (e.g., alarms, storage options).

  • Stationary devices: Integrated into monitoring systems. For continuous monitoring in intensive care units or operating rooms.

Handheld pulse oximeters are ideal for:

  • Emergency services and emergency medicine

  • Transfer and transport monitoring

  • Hospital wards without central monitoring

  • Nursing homes and home visits

Modern handheld pulse oximeters with high-quality sensors and algorithms achieve a measurement accuracy of ±2% at an SpO₂ between 70%–100%. Even with movement or low perfusion, premium devices like our handheld pulse oximeters HS-10A and HS-20A provide stable values.

This feature allows for reliable measurements even with restricted peripheral circulation, e.g., in shock, hypothermia, or vasoconstriction – a crucial advantage in emergency services.

Yes. Many of our professional handheld pulse oximeters have freely adjustable alarm thresholds for SpO₂ and pulse rate – both visually and audibly. This improves patient safety during monitoring.

Handheld pulse oximeters typically support:

  • Finger clip sensorsfor adults

  • Soft sensorsfor longer applications

  • Child sensors / newborn sensorsfor pediatric use

Compatibility with SpO₂ sensors is model-dependent and should be checked before purchase.